Air compressor operation

Air compressor is one of the main mechanical power equipments of many enterprises. It is very necessary to keep the air compressor safe. Strict implementation of the air compressor operating procedures not only helps to extend the service life of the air compressor, but also ensures the safety of the air compressor operator. Let us understand the air compressor operating procedures.


First, before the operation of the air compressor, you should pay attention to the following issues:


1. Keep the oil in the oil pool within the scale. Before the air compressor is operated, check that the oil in the oiler should not be lower than the mark value.


2. Check whether the moving parts are flexible, whether the joint parts are tight, whether the lubrication system is normal, and whether the motor and electrical control equipment are safe and reliable.


3. Check whether the protective device and safety accessories are intact before the operation of the air compressor.


4. Check if the exhaust line is unblocked.


5. Turn on the water source and open each inlet valve to make the cooling water unblocked.


Second, the air compressor operation should pay attention to the long-term deactivation after the first start, must be checked by the car, pay attention to whether there is impact, stuck or abnormal sound.


Third, the machine must be started under no load condition. After the no-load operation is normal, the air compressor is gradually put into the load operation.


4. When the air compressor is in operation, after normal operation, always pay attention to various meter readings and adjust them at any time.


5. In the operation of the air compressor, the following conditions should also be checked:


1. Whether the motor temperature is normal and whether the reading of each meter is within the specified range.


2. Whether the running sound of each machine is normal.


3. Whether the suction valve cover is hot or not, and the sound of the valve is normal.


4. Whether the various safety protection devices of the air compressor are reliable.


6. After the air compressor is operated for 2 hours, the oil and water in the oil-water separator, the intercooler and the after-cooler should be discharged once, and the oil and water in the storage tank should be discharged once per shift.


7. When the following conditions are found during the operation of the air compressor, stop immediately, find out the cause, and eliminate it.


1. The lubricating oil is terminated or the cooling water is terminated.


2. The water temperature suddenly rises or falls.


3. The exhaust pressure suddenly rises and the safety valve fails.


4. The load suddenly exceeds the normal value.


5. The mechanical noise is abnormal.


6. An abnormality has occurred in the motor or electrical equipment.


Fired Heater

Flame heater is a kind of equipment that uses the heat energy generated by the combustion of flame to heat. It usually consists of a fuel supply system, an ignition system, a combustion chamber, a Heat Exchanger and an emission system. The fuel supply system usually uses liquefied gas, natural gas or diesel as the fuel, the ignition system is used to ignite the fuel, the combustion chamber is where the fuel is burned, the heat exchanger is used to transfer the heat generated by the combustion to the heated object, and the emission system is used to discharge the exhaust gas produced by the combustion. Flame heater is widely used in industrial production, construction sites, wild camping and other occasions, has the advantages of fast heating, high efficiency, easy operation and so on.


The main business scope is various heaters, waste heat boilers, pressure vessels, supportingair preheaters, air coolers, furnace accessories and accessories, and provide equipment installation, with EPC ability of projects. At present, our customers have covered all large and medium-sized petrochemical enterprises in China and established long-term strategic cooperative partnership with them. Products are exported to Southeast Asia, Middle East, and other regions.


Fired Heater,Hydrogenation Project,Hydrogen Production Eguipment,Heating Furnace Equipment

Jiangsu Gelan Environmental Technology Co., LTD , https://www.glkj2010.com